I-TH-G Series Layer2 Ephethwe I-Ethernet Switch 2xGigabit SFP, 8×10/100/1000Base-T 4xGigabit Combo( RJ45/SFP) 24×10/100/1000Base-T Port
Le Gigabit Layer 2 Managed Switch ifakwe 8(24)x Gigabit Ethernet Ports kanye 2(4)x Gigabit SFP Ports ezijwayelana ngokuzenzakalelayo nemodi ye-duplex egcwele noma ehhafu. Ubuchwepheshe bokuzifundela kwekheli le-MAC lokushintshwa buvumela ukudluliswa kwedatha ngaphandle kwamaphutha, kuyilapho imodi yayo yesitolo nokudlulisela phambili ivimbela amaphakethe alimele ukuthi angagcwali kunethiwekhi. Ukwengeza, le swishi ifaka umsebenzi wokulawula ukugeleza ongavimbela inani elikhulu ledatha esheshayo ukuthi libe nomthelela kunethiwekhi.
Iswishi inikeza imisebenzi ethuthukisiwe yokuphatha inethiwekhi njengenethiwekhi yendandatho engasasebenzi, i-VLAN, iqoqo, i-QoS, isilawuli sesivinini, isithombe sembobo, i-alamu yephutha, nokuthuthukiswa kwe-firmware ku-inthanethi. Isatshalaliswa kabanzi kuzimo zokufinyelela ze-Ethernet zamabhizinisi amancane kuya kwamaphakathi, amakhefi e-inthanethi, amahhotela, izikole, nokunye. Ngezici zayo ezibanzi, le swishi inikeza ukusebenza kwenethiwekhi okuthembekile nokusebenza kahle futhi isiza amabhizinisi ukuthi afinyelele ukuxhumana okungenazihibe nokudluliswa kwedatha.
● Sekela i-IEEE802.3/ IEEE802.3u/ IEEE802.3ab/IEEE802.3z, gcina bese-phambili
● Imodi yokulawula ukugeleza: i-full-duplex isebenzisa i-IEEE 802.3x ejwayelekile, i-half-duplex isebenzisa izinga lokucindezela Emuva
● I-port auto flip yokusekela (Auto MDI/MDIX)
● Inkomba yephaneli eqapha isimo kanye nokuhlaziya ukwehluleka kosizo
● Sekela ukuqinisekiswa kwembobo okungu-802.1x, isekela ukuqinisekiswa kwe-AAA, isekela ukuqinisekiswa kwe-TACACS+
● Sekela iWEB, TELNET, CLI, SSH, SNMP, RMON management
● Ukuvikelwa Kokuhlinzwa: Okujwayelekile 4KV, Differential 2KV, ESD 8KV air, 6KV contact
I/O Interface | ||
Okokufaka kwamandla | I-AC 100-240V, 50/60Hz | |
Imbobo Elungisiwe | P/N | Imbobo Elungisiwe |
I-TH-G0208M2-R | 8*10/ 100/ 1000Mbps Imbobo ye-Ethernet | |
2*1000Mbps SFP Port | ||
1*I-Console Port | ||
I-TH-G0424M2-Z | 24 x 10/ 100/ 1000Mbps Imbobo | |
4 x 1000M Combo (RJ45/SFP) Imbobo | ||
1 x RJ45 Console Port | ||
Ukusebenza | ||
Umkhawulokudonsa | 20Gbps (okungavimbi)/56Gbps | |
Izinga lokudlulisa iphakethe | 14.88Mpps/41.66Mpps | |
Iphakeji Buffer | 4M | |
Amandla enkumbulo | 128MB | |
Amandla weFlash | 16MB | |
Ikheli le-MAC | 8K | |
Ama-VLAN | 4096 | |
I-Jumbo Frame | 9.6Kbytes | |
Imodi yokudlulisa | Gcina futhi uye phambili | |
MTBF | 100000 amahora | |
Okujwayelekile | ||
Iphrothokholi yenethiwekhi | IEEE802.3: 10Base-T | |
IEEE802.3u: 100Base-TX | ||
IEEE802.3ab : 1000Base-TX | ||
IEEE802.3z :1000Base- FX | ||
IEEE 802.3x: Ukulawula ukugeleza | ||
IEEE 802.1ab : LLDP/LLDP- MED (Iphrothokholi Yokutholwa Kwesendlalelo Sesixhumanisi) | ||
I-IEEE 802.1p: I-LAN Layer QoS/CoS Protocol Priorization Traffic (umsebenzi wokuhlunga okuningiliziwe) | ||
IEEE 802.1q: Ukusebenza kwebhuloho le-VLAN | ||
IEEE 802.1x: Ukulawulwa Kokufinyelela Kwekhasimende/Iseva kanye Nephrothokholi Yokuqinisekisa | ||
IEEE 802.3ad : Indlela evamile yokwenza ukuhlanganisa isixhumanisi | ||
IEEE 802.1d : STP | ||
IEEE 802.1s: MSTP | ||
IEEE 802.1w: RSTP | ||
Izinga Lemboni | I-EMI: I-FCC Ingxenye 15 CISPR (EN55032) isigaba A | |
I-EMS: EN61000-4-2 (ESD), | ||
I-EN61000-4-5 (Surge) | ||
I-Network Medium | ||
I-10Base-T: I-Cat3/4/5 noma ngaphezulu kwe-UTP(≤100m) | ||
100Base-TX: Cat5 noma ngaphezulu kwe-UTP(≤100m) | ||
1000Base-TX: Cat5 noma ngaphezulu kwe-UTP (≤100m) | ||
Izimpawu ze-Optical | Imodi eminingi: 850/ 1310nm (0-2KM) | |
Imodi eyodwa: 1310/ 1550/ 1490nm (0- 120KM) | ||
Izitifiketi | ||
Isitifiketi Sokuphepha | CE, FCC, RoHS | |
Imvelo | ||
Indawo Yokusebenzela | Izinga Lokushisa Lokusebenza: – 10–50.C | |
Izinga Lokushisa Lokugcina: -40 ~ 70.C | ||
Umswakamo osebenzayo: 10% ~ 90%, awunciphisi | ||
Izinga Lokushisa Lesitoreji: 5% ~ 90%, alijiki | ||
Inkomba | ||
Izinkomba ze-LED | PWR, SYS, Link, ACT | |
Omakhenikha | ||
Usayizi Wesakhiwo | Usayizi womkhiqizo: 268 * 181 * 44mm | |
Usayizi wephakheji: 312 * 262 * 84mm | ||
Isisindo Somkhiqizo: 1.01KG | ||
Isisindo Somkhiqizo: 1.54KG | ||
/ | ||
Ubukhulu bomkhiqizo (L*W*H) : 440* 284*44mm | ||
Ubukhulu bephakheji (L*W*H): 495*350*103mm | ||
NW: 3.5kg | ||
Isisindo: 4.25kg | ||
Ukupakisha Ulwazi | IZINSIZA: 540*435*332mm | |
Ukupakisha Ubuningi: 10PCS | ||
Isisindo sokupakisha: 16.4KG | ||
/ | ||
I-Carton MEAS: 592 * 510 * 375mm | ||
Ukupakisha Ubuningi: amayunithi ama-5 | ||
Isisindo Sokupakisha: 22.5KG | ||
Umsebenzi Wesoftware Yesendlalelo sesi-2 | ||
Ukuphathwa Kwechweba | Nika amandla/ Khubaza Imbobo | |
Isivinini, i-Duplex, i-MTU Setting | ||
Ukulawula ukugeleza | ||
Hlola Ulwazi Lwechweba | ||
I-Port Mirroring | Isekela kokubili i-side-way port mirroring | |
I-Port Speed Limit | Isekela i-port-based input / output bandwidth management | |
Ukuhlukaniswa kwePort | Sekela ukuhlukaniswa kwembobo ye-downlink, futhi ingaxhumana nembobo ye-uplink | |
Ukucindezela Kwesiphepho | Isekela i-unicast engaziwa, i-multicast, i-multicast engaziwa, ukucindezela uhlobo lokusakaza kwesiphepho | |
Ukucindezelwa kwesiphepho okusekelwe kumthethonqubo womkhawulokudonsa kanye nokuhlunga kwesiphepho | ||
Ukuhlanganiswa Kwesixhumanisi | Sekela ukuhlanganisa okwenziwa ngesandla okumile | |
Sekela ukuhlanganisa okuguquguqukayo kwe-LACP | ||
I-VLAN | Ukufinyelela | |
I-TrunkHybrid | ||
Imbobo yokusekela, iphrothokholi, ukwahlukanisa kwe-VLAN okusekelwe ku-MAC | ||
Sekela ukubhaliswa kwe-VLAN eguqukayo ye-GVRP | ||
I-VLAN yezwi | ||
I-MAC | Sekela ukwengeza okumile, ukususwa | |
Umkhawulo wokufunda wekheli le-MAC | ||
Sekela isilungiselelo sesikhathi sokuguga esiguqukayo | ||
Isihlahla esinwebekayo | Sekela iphrothokholi yesihlahla enwebekayo ye-STP | |
Isekela i-RSTP Rapid Spanning Tree Protocol | ||
Isekela i-MSTP Rapid Spanning Tree Protocol | ||
Ukusakaza okuningi | Sekela ukwengeza okumile, ukususwa | |
I-IGMP - ukuhlaziya | ||
Sekela i-MLD- Snooping | ||
Sekela i-v1/2/3 imonitha yokusakaza okuningi enamandla | ||
I-DDM | Sekela i-SFP/SFP+DDM | |
I-ACL | Ngokusekelwe kumthombo we-MAC, indawo ye-MAC, uhlobo lwephrothokholi, i-IP yomthombo, i-IP okuyiwa kuyo, imbobo ye-L4 | |
Qos | Ngokusekelwe kusigaba esingu-802.1p (COS). | |
Ngokusekelwe kusigaba se-DSCP | ||
Ukuhlukaniswa ngokusekelwe ku-IP yomthombo, i-IP yendawo, kanye nenombolo yembobo | ||
Sekela i-SP, isu lokuhlela le-WRR | ||
Ukusekela isilinganiso sokugeleza komkhawulo CAR | ||
I-LLDP | Sekela iphrothokholi yokutholwa kwesixhumanisi se-LLDP | |
Izilungiselelo zomsebenzisi | Engeza/susa abasebenzisi | |
Ilogi | Ukungena ngemvume komsebenzisi, ukusebenza, isimo, imicimbi | |
Anti- attack | Ukuzivikela kwe-DOS | |
Sekela ukuvikelwa kwe-CPU futhi ukhawule izinga lokuthumela amaphakethe we-cpu | ||
Ukubophezela kwe-ARP (IP, MAC, PORT ebopha) | ||
Isitifiketi | Sekela 8 0 2 . 1 x ukufakazela ubuqiniso kwembobo | |
Sekela isitifiketi se-AAA | ||
Ukuxilongwa kwenethiwekhi | Ukusekela i-ping, i-telnet, ukulandelela | |
Ukuphathwa Kwesistimu | Ukusetha kabusha idivayisi, ukulungisa londoloza/buyisela, thuthukisa ukuphathwa, ukulungiselelwa kwesikhathi, njll. | |
I-CLI | Sekela ukuphathwa komugqa womyalo we-serial port | |
I-SSH | Sekela ukuphathwa okukude kwe-SSHv1/2 | |
I-MACTELNET | Sekela ukuphathwa okukude kwe-telnet | |
IWEBH | Izilungiselelo ze-Support Layer 2, Layer 2 kanye ne-Layer 3 monitor | |
I-LLDP | Sekela iphrothokholi yokutholwa kwesixhumanisi se-LLDP | |
Izilungiselelo zomsebenzisi | Engeza/susa abasebenzisi | |
Ilogi | Ukungena ngemvume komsebenzisi, ukusebenza, isimo, imicimbi | |
Anti- attack | Ukuzivikela kwe-DOS | |
Sekela ukuvikelwa kwe-CPU futhi ukhawule izinga lokuthumela amaphakethe we-cpu | ||
Ukubophezela kwe-ARP (IP, MAC, PORT ebopha) | ||
Isitifiketi | Sekela 8 0 2 . 1 x ukufakazela ubuqiniso kwembobo | |
Sekela isitifiketi se-AAA | ||
Ukuxilongwa kwenethiwekhi | Ukusekela i-ping, i-telnet, ukulandelela | |
Ukuphathwa Kwesistimu | Ukusetha kabusha idivayisi, ukulungisa londoloza/buyisela, thuthukisa ukuphathwa, ukulungiselelwa kwesikhathi, njll. | |
I-CLI | Sekela ukuphathwa komugqa womyalo we-serial port | |
I-SSH | Sekela ukuphathwa okukude kwe-SSHv1/2 | |
I-TELNET | Sekela ukuphathwa okukude kwe-telnet | |
IWEBH | Izilungiselelo ze-Support Layer 2, Layer 2 kanye ne-Layer 3 monitor | |
I-SNMP
| I-SNMP V1/V2/V3 | |
Isicupho sokusekela: ColdStart, WarmStart, Link Down, Xhumanisa phezulu | ||
I-RMON | Sekela i-RMON v1 | |
Eminye imisebenzi | Sekela i-DHCP Snooping, Option82 | |
Sekela ukutholwa kwe-ARP enamandla | ||
Sekela isitifiketi se-TACACS+ | ||
Sekela isitifiketi se-DNS | ||
Sekela izilungiselelo zokuphepha kwembobo | ||
Sekela iphrothokholi ye-MVR |