I-TH-G0208M2-R Layer2 Ephethwe I-Ethernet Switch 2xGigabit SFP, 8×10/100/1000Base-T

Inombolo Yemodeli:I-TH-G0208M2-R

Ibhrendi:Todahika

  • I-port auto flip yokusekela (i-Auto MDI/MDIX)
  • Inkomba yephaneli eqapha isimo nokuhlaziya ukwehluleka kosizo

Imininingwane Yomkhiqizo

Izici

Uku-oda Ulwazi

Imininingwane

Ubukhulu

Omaka bomkhiqizo

Incazelo Yomkhiqizo

I-Gigabit Layer 2 Managed Switch isekela Izimbobo ze-8xGigabit Ethernet + 2xGigabit SFP Ports, ukuzivumelanisa ngokuzenzakalelayo nemodi ye-duplex egcwele noma uhhafu we-duplex. Ukuzifundela kwekheli le-MAC kuqinisekisa ukudluliswa kwedatha okunganaphutha, futhi imodi yesitolo neyokudlulisela phambili ivimbela amaphakethe alimele ekukhukhuleni kunethiwekhi . Umsebenzi wokulawula ukugeleza ungavimbela umthelela wenani elikhulu ledatha esheshayo kunethiwekhi.

Lolu chungechunge lokushintshwa luhlinzeka ngemisebenzi yokuphatha inethiwekhi ethuthukisiwe: inethiwekhi yendandatho engafuneki, i-VLAN, iqoqo, i-QoS, ukulawula isivinini, isithombe sechweba, i-alamu yephutha kanye nokuthuthukiswa kwe-firmware ye-inthanethi, esetshenziswa kabanzi ezimweni zokufinyelela kwe-Ethernet ezifana namabhizinisi amancane naphakathi, amathofi e-Inthanethi. , amahhotela, izikole, njll.

I-TH-8G0024M2P

  • Okwedlule:
  • Olandelayo:

  • ● Sekela i-IEEE802.3/ IEEE802.3u/ IEEE802.3ab/IEEE802.3z, gcina bese-phambili

    ● Imodi yokulawula ukugeleza: i-full-duplex isebenzisa i-IEEE 802.3x ejwayelekile, i-half-duplex isebenzisa izinga lokucindezela Emuva

    I-port auto flip yokusekela (i-Auto MDI/MDIX)

    ● Inkomba yephaneli eqapha isimo kanye nokuhlaziya ukwehluleka kosizo

    ● Sekela ukuqinisekiswa kwembobo okungu-802.1x, isekela ukuqinisekiswa kwe-AAA, isekela ukuqinisekiswa kwe-TACACS+

    ● Sekela iWEB, TELNET, CLI, SSH, SNMP, RMON management

    ● Ukuvikelwa Kokuhlinzwa: Okujwayelekile 4KV, Differential 2KV, ESD 8KV air, 6KV contact

    INGXENYE NO. DESCRIPTION
    I-TH-G0208M2-R I-Layer2 Managed Ethernet Switch 2xGigabit SFP, 8×10/100/1000Base-T

    I/O Interface

    Okokufaka kwamandla

    I-AC 100-240V, 50/60Hz

    Imbobo Elungisiwe

    8*10/100/1000Mbps Imbobo ye-Ethernet

    2*1000Mbps SFP Port

    1*I-Console Port

    Ukusebenza

    Umkhawulokudonsa

    20Gbps (okungavimbi)

    Izinga lokudlulisa iphakethe

    14.88Mpps

    Iphakeji Buffer

    4M

    Amandla enkumbulo

    128MB

    Amandla weFlash

    16MB

    Ikheli le-MAC

    8K

    Ama-VLAN

    4096

    I-Jumbo Frame

    9.6Kbytes

    Imodi yokudlulisa

    Gcina futhi uye phambili

    MTBF

    100000 amahora

    Okujwayelekile

    Iphrothokholi yenethiwekhi

    IEEE802.3: 10Base-T

    IEEE802.3u: 100Base-TX

    IEEE802.3ab: 1000Base-TX

    IEEE802.3z :1000Base-FX

    IEEE 802.3x: Ukulawula ukugeleza

    IEEE 802.1ab: LLDP/LLDP-MED (Iphrothokholi Yokutholwa Kwesendlalelo Sesixhumanisi)

    I-IEEE 802.1p: I-LAN Layer QoS/CoS Protocol Priorization Traffic (umsebenzi wokuhlunga okuningiliziwe)

    IEEE 802.1q: Ukusebenza kwebhuloho le-VLAN

    IEEE 802.1x: Ukulawulwa Kokufinyelela Kwekhasimende/Iseva kanye Nephrothokholi Yokuqinisekisa

    IEEE 802.3ad: Indlela evamile yokwenza ukuhlanganisa isixhumanisi

    IEEE 802.1d: STP

    IEEE 802.1s: MSTP

    IEEE 802.1w: RSTP

    Izinga Lemboni

    I-EMI: I-FCC Ingxenye 15 CISPR (EN55032) isigaba A

    I-EMS: EN61000-4-2 (ESD),

    I-EN61000-4-5 (Surge)

    I-Network Medium

    I-10Base-T: I-Cat3/4/5 noma ngaphezulu kwe-UTP(≤100m)

    100Base-TX: Cat5 noma ngaphezulu kwe-UTP(≤100m)

    1000Base-TX: Cat5 noma ngaphezulu kwe-UTP (≤100m)

    Izimpawu ze-Optical

    Imodi eminingi: 850/1310nm (0-2KM)

    Imodi eyodwa: 1310/1550/1490nm (0-120KM)

    Izitifiketi

    Isitifiketi Sokuphepha

    CE, FCC, RoHS

    Imvelo

    Indawo Yokusebenzela

    Izinga Lokushisa Lokusebenza: -10 ~ 50°C

    Izinga Lokushisa Lesitoreji: -40~70°C

    Umswakamo osebenzayo: 10% ~ 90%, awunciphisi

    Izinga Lokushisa Lesitoreji: 5% ~ 90%, alijiki

    Inkomba

    Izinkomba ze-LED

    PWR, SYS, Link, ACT

    Omakhenikha

    Usayizi Wesakhiwo

    Usayizi womkhiqizo: 268 * 181 * 44mm

    Usayizi wephakheji: 312 * 262 * 84mm

    Isisindo Somkhiqizo: 1.01KG

    Isisindo Somkhiqizo: 1.54KG

    Ukupakisha Ulwazi

    IZINSIZA: 540*435*332mm

    Ukupakisha Ubuningi: 10PCS

    Isisindo sokupakisha: 16.4KG

    Umsebenzi Wesoftware Yesendlalelo sesi-2

    Ukuphathwa Kwechweba

    Nika amandla/Khubaza Imbobo

    Isivinini, i-Duplex, i-MTU Setting

    Ukulawula ukugeleza

    Hlola Ulwazi Lwechweba

    I-Port Mirroring

    Isekela kokubili i-side-way port mirroring

    I-Port Speed ​​Limit

    Isekela okokufaka okusekelwe echwebeni / ukuphathwa komkhawulokudonsa okukhiphayo

    Ukuhlukaniswa kwePort

    Sekela ukuhlukaniswa kwembobo ye-downlink, futhi ingaxhumana nembobo ye-uplink

    Ukucindezela Kwesiphepho

    Isekela i-unicast engaziwa, i-multicast, i-multicast engaziwa,

    ukucindezela uhlobo lokusakaza kwesiphepho

    Ukucindezelwa kwesiphepho okusekelwe kumthethonqubo womkhawulokudonsa nokuhlunga kwesiphepho

    Ukuhlanganiswa Kwesixhumanisi

    Sekela ukuhlanganisa okwenziwa ngesandla okumile

    Sekela ukuhlanganisa okuguquguqukayo kwe-LACP

    I-VLAN

    Ukufinyelela

    Isiqu

    Ingxubevange

    Imbobo yokusekela, iphrothokholi, ukwahlukanisa kwe-VLAN okusekelwe ku-MAC

    Sekela ukubhaliswa kwe-VLAN eguqukayo ye-GVRP

    I-VLAN yezwi

    I-MAC

    Sekela ukwengeza okumile, ukususwa

    Umkhawulo wokufunda wekheli le-MAC

    Sekela isilungiselelo sesikhathi sokuguga esiguqukayo

    Isihlahla esinwebekayo

    Sekela iphrothokholi yesihlahla enwebekayo ye-STP

    Isekela i-RSTP Rapid Spanning Tree Protocol

    Isekela i-MSTP Rapid Spanning Tree Protocol

    Ukusakaza okuningi

    Sekela ukwengeza okumile, ukususwa

    I-IGMP-snooping

    Sekela i-MLD-Snooping

    Sekela i-v1/2/3 imonitha yokusakaza okuningi enamandla

    I-DDM

    Sekela i-SFP/SFP+DDM

    I-ACL

    Ngokusekelwe kumthombo we-MAC, indawo ye-MAC, uhlobo lwephrothokholi, i-IP yomthombo, i-IP okuyiwa kuyo, imbobo ye-L4

    Qos

    Ngokusekelwe kusigaba esingu-802.1p (COS).

    Ngokusekelwe kusigaba se-DSCP

    Ukuhlukaniswa ngokusekelwe ku-IP yomthombo, i-IP yendawo, kanye nenombolo yembobo

    Sekela i-SP, isu lokuhlela le-WRR

    Ukusekela isilinganiso sokugeleza komkhawulo CAR

    I-LLDP

    Sekela iphrothokholi yokutholwa kwesixhumanisi se-LLDP

    Izilungiselelo zomsebenzisi

    Engeza/susa abasebenzisi

    Ilogi

    Ukungena ngemvume komsebenzisi, ukusebenza, isimo, imicimbi

    Anti-attack

    Ukuzivikela kwe-DOS

    Sekela ukuvikelwa kwe-CPU futhi ukhawule izinga lokuthumela amaphakethe we-cpu

    Ukubophezela kwe-ARP (IP, MAC, PORT ebopha)

    Isitifiketi

    Sekela ukuqinisekiswa kwembobo okungu-802.1x

    Sekela isitifiketi se-AAA

    Ukuxilongwa kwenethiwekhi

    Ukusekela i-ping, i-telnet, ukulandelela

    Ukuphathwa Kwesistimu

    Ukusetha kabusha idivayisi, ukulungisa londoloza/buyisela, thuthukisa ukuphathwa, ukulungiselelwa kwesikhathi, njll.

    I-CLI

    Sekela ukuphathwa komugqa womyalo we-serial port

    I-SSH

    Sekela i-SSHv1/2 ukuphathwa okukudeTELNET

    Sekela ukuphathwa okukude kwe-telnet

    IWEBH

    Izilungiselelo ze-Support Layer 2, Layer 2 kanye ne-Layer 3 monitor

    I-LLDP

    Sekela iphrothokholi yokutholwa kwesixhumanisi se-LLDP

    Izilungiselelo zomsebenzisi

    Engeza/susa abasebenzisi

    Ilogi

    Ukungena ngemvume komsebenzisi, ukusebenza, isimo, imicimbi

    Anti-attack

    Ukuzivikela kwe-DOS

    Sekela ukuvikelwa kwe-CPU futhi ukhawule izinga lokuthumela amaphakethe we-cpu

    Ukubophezela kwe-ARP (IP, MAC, PORT ebopha)

    Isitifiketi

    Sekela ukuqinisekiswa kwembobo okungu-802.1x

    Sekela isitifiketi se-AAA

    Ukuxilongwa kwenethiwekhi

    Ukusekela i-ping, i-telnet, ukulandelela

    Ukuphathwa Kwesistimu

    Ukusetha kabusha idivayisi, ukulungisa londoloza/buyisela, thuthukisa ukuphathwa, ukulungiselelwa kwesikhathi, njll.

    I-CLI

    Sekela ukuphathwa komugqa womyalo we-serial port

    I-SSH

    Sekela ukuphathwa okukude kwe-SSHv1/2

    I-TELNET

    Sekela ukuphathwa okukude kwe-telnet

    IWEBH

    Izilungiselelo ze-Support Layer 2, Layer 2 kanye ne-Layer 3 monitor

    I-SNMP

    I-SNMP V1/V2/V3

    Uxhaso lokusekela: ColdStart, WarmStart, LinkDown, LinkUp

    I-RMON

    Sekela i-RMON v1

    Eminye imisebenzi

    Sekela i-DHCP Snooping, Option82

    Sekela ukutholwa kwe-ARP enamandla

    Sekela isitifiketi se-TACACS+

    Sekela isitifiketi se-DNS

    Sekela izilungiselelo zokuphepha kwembobo

    Sekela i-MVR protoco

    Ubukhulu

    Bhala umyalezo wakho lapha futhi usithumelele wona