I-TH-GC Series Lerser2 Iphethwe i-Ethernet Shintsha i-4xgigabit Combo (RJ45 / SFP) 16 × 10/1000base-T Poe
I-Gigabit Leyar 2 ephethwe Straw switch iwukushintsha okuluhlaza okonga amandla okuzimela. Nge-IC ekhwalithi ephezulu ne-High-Speed Network ne-Chip ezinzile kakhulu, amachweba e-PoE ahlangana neee802.3AF 15.4W ne-IEEE802.3at 30w. Le modeli inganikeza ukuxhumana okungenamthungo kwe-10 / 100/1000m ethernet, kanye ne-poe port port kungabona ngokuzenzakalelayo futhi kunamandla amadivayisi anikezwe amandla ahambisana namazinga weeee802.3AF / ATS. Amadivaysi angewona ama-Poe anikwe amandla futhi adlulisela idatha kuphela.

● Dlulwa idatha yamakhamera wokubhekwa kwenethiwekhi
● Ukusekelwa i-IEEEE802.3 / IEEEE802.3U / IEEEE802.3UIEEE802.3UIEEE802.3UEEEEE802.3AB / IEEEE802.3Z, IEEEE802.3Z / IEEEE802.3AF / AT, STORED
● Iyahambisana ne-IEEEE802.3AT (30W) ne-IEEEE802.3AF (15.4W)
● IPortnet Port isekela imisebenzi engu-10/100 / 1000M eguquguqukayo ne-PoE
● Isikhombisi sephaneli siqapha isimo futhi sisiza ukuhlaziya ukwehluleka
● Ukuxhaswa kokuqinisekiswa kwetheku okungu-802.1x, ukusekela ubuqiniso be-AAA, ukusekela ama-Tacacs + okuqinisekisiwe; Izilungiselelo ze-DOS Attack Defense, izilungiselelo ze-ACL
● Ukusekelwa kwewebhu, iTelnet, Cli, SSH, SNMP, ROMMAN PATROMS
● Sekela ukuphathwa kwamandla kwe-poe kanye ne-poe watchdog
● Ukuhlinzwa kokuvikelwa kombani: Imodi Ejwayelekile 4KV, Imodi Ehlukile 2KV, ESD 15KV
P / n | Ukufanisa |
Th-gc0416pm2-z200w | I-Layer2 iphethwe i-Ethernet switchn 4x1gigabit combo (RJ45 / SFP)I-16 × 10 / 100/1000base-T Poe Port, Amandla Wangaphakathi Wokunikezela nge-52v / 3.8a, 200w |
Th-gc0416pm2-z300w | I-Layer2 iphethwe i-Ethernet switchn 4x1gigabit combo (RJ45 / SFP)I-16 × 10 / 100/1000base-T Poe Port, Amandla Wangaphakathi Wokunikezela nge-52v / 5.76a, 300W |
Th-gc0424pm2-z300w | I-Layer2 iphethwe i-Ethernet Shintsha i-4xgigabit Combo (RJ45 / SFP) 24 × 10/1000base-T Poe Port, Amandla Wangaphakathi Ukunikezwa kwe-52v / 5.76a, 300W |
Th-gc0424pm2-z400w | I-Layer2 iphethwe i-Ethernet switchch 4xgigabit combo (RJ45 / SFP) 24 × 10/1000base-T Poe Port, Ukuhlinzekwa Kwangaphakathi Kwamandla 52v / 7009A, 400W |
I / O interface | ||
Ukufakwa kwamandla | Faka i-AC 110-240V, 50 / 60hz | |
Imbobo elungisiwe | P / n | Imbobo elungisiwe |
Th-gc0416pm2-z200w | I-16 x 10 / 100/1000mbps poe port | |
4 x 1000m combo (RJ45 / SFP) Port | ||
1 x rj45 ikhonsoli port | ||
Th-gc0416pm2-z300w | I-16 x 10 / 100/1000mbps poe port | |
4 x 1000m combo (RJ45 / SFP) Port | ||
1 x rj45 ikhonsoli port | ||
Th-gc0424pm2-z300w | I-24 x 10 / 100/1000mbps Poe Port | |
4 x 1000m combo (RJ45 / SFP) Port | ||
1 x rj45 ikhonsoli port | ||
Th-gc0424pm2-z400w | I-24 x 10 / 100/1000mbps Poe Port | |
4 x 1000m combo (RJ45 / SFP) Port | ||
1 x rj45 ikhonsoli port | ||
Ukwenza | ||
Ukushintsha amandla | I-56GBPS | |
Phendukela | 41.66MPPS | |
I-Packet Buffer | I-4MB | |
Imemori ye-Flash | I-16MB | |
DDR SDRAM | I-128BB | |
Ikheli le-MAC | 8K | |
Uhlaka lweJumbo | 9.6kbytes | |
Ubuhle beVlans | 4096 | |
Imodi yokudlulisa | Gcina futhi phambili | |
I-MTBF | Amahora angama-100000 | |
-Vamile | ||
Iphrothokholi yenethiwekhi | Iee 802.3: I-Ethernet Mac Protocol | |
Iee 802.3i: 10Base-T Ethernet | ||
Iee 802.3U: I-100Base-TX Ethernet | ||
Iee 802.3AB: 1000base-T gigabit ethernet | ||
Iee 802.3Z: 1000base-X gigabit ethernet (fiber optical) | ||
Iee 802.3.3AZ: Energy Energy Exernet | ||
Iee 802.3AD: Indlela ejwayelekile yokwenza ukuhlanganiswa kwesixhumanisi | ||
Iee 802.3x: Ukulawulwa kokugeleza | ||
IEEE 802.1BAB: LLDP / LLDP-Med (I-Link Wears Discovery Protocol) | ||
IEEE 802.1P: I-Lan Laner Qos / Cos Protocol Partimization Partimization (Multicast | ||
Umsebenzi wokuhlunga) | ||
IEEE 802.1Q: Ukusebenza kwe-VLAN BRIDE | ||
IEEE 802.1X: Ukulawulwa kokufinyelela kweklayenti / iseva kanye nokufakazela ubuqiniso protocol | ||
Iee 802.1D: STP; Iee 802.1s: MSTP; Iee 802.1w: RSTP | ||
Protocol poe | Ieee802.3AF (15.4W); IEEE802.3AT (30W) | |
Indinganimba yezimboni | I-EMI: I-FCC Ingxenye 15 CISPR (EN55032) Class a | |
EMS: En61000-4-2 (ESD), EN61000-4-4 (EFT), En61000-4-5 (Surge) | ||
Ukushaqeka: IEC 60068-2-27 | ||
Ukuwa kwamahhala: IEC 60068-32 | ||
Ukudlidliza: IEC 60068-2-6 | ||
Inethiwekhi medium | I-10base-T: Cat3, 4, 5 noma ngenhla i-UTP (≤100m) | |
I-100Base-TX: I-Cat5 noma ngenhla i-UTP (≤100m) | ||
I-1000Base-TX: I-Cat5 noma ngenhla i-UTP (≤100m) Optical | ||
I-multimode fiber: 1310nm, 2km | ||
Imodi yemodi eyodwa: 1310nm, 20/40 km; I-1550nm, 60/80/100 / 120km | ||
Ukuvikela | ||
Isitifiketi Sokuphepha | Ce / FCC / FCC / ROH | |
Indawo ezungezile | ||
Indawo Yokusebenza | Ukushisa okusebenzayo: -20 ~ 55 ° C | |
Ukushisa kokugcina: 40 ~ 85 ° C | ||
Umswakama osebenzayo: 10% ~ 90%,Okungaphenduli | ||
Ukushisa kwesitoreji: 5% ~ 90%,Okungaphenduli | ||
Ukuphakama kokusebenza: Amamitha aphezulu10,000 | ||
Isitoreji se-Heigh: Maximum 10,000 | ||
Inkomba | ||
Izinkomba ze-LED | I-PWR (Ukunikezwa Kwamandla) | |
Ama-sys (uhlelo) | ||
1-24 Poe & Act (Poe) | ||
1-24 Link & Act (Link & Act) | ||
25-28 isixhumanisi (isixhumanisi) | ||
25-28 Act (Act) | ||
Ukucwilisa switch | Setha kabusha | |
-Omshini | ||
Usayizi wesakhiwo | Ubukhulu bomkhiqizo (l * w * h): 440 * 284 * 44mm | |
I-Package Macciension (l * w * h): 495 * 350 * 103mm | ||
NW: 3.5kg | ||
Gw: 4.25kg | ||
Ukupakisha imininingwane | I-Carton Some: 592 * 510 * 375mm | |
Ukupakisha Qty: amayunithi ama-5 | ||
Ukupakisha isisindo: 22.5kg | ||
Umsebenzi wesoftware 2 | ||
Ukuphathwa kwe-port | Nika amandla / khubaza i-Port | |
Isivinini, duplex, i-MTU Setting | ||
Ukulawula Ukugeleza | ||
Ukuhlolwa kolwazi lwe-port | ||
Izibuko Zetheku | Isekela zombili izibuko eziseceleni | |
Umkhawulo wejubane lePort | Usekela Ukufakwa kwe-bandwidth okususelwa ethekwini / kokukhipha | |
I-Port Solate | Sekela i-DownLink Port Solate, futhi ungakwazi ukuxhumana ne-Port Port | |
Ukucindezelwa kwesivunguvungu | Usekela i-unicast engaziwa, i-multicast, i-multicast engaziwa, ukusakazwa kwesivunguvungu sohlobo lwesivunguvungu | |
Ukucindezelwa kwesivunguvungu kususelwa kumkhawulokudonsa kanye nokuhlunga kwesivunguvungu | ||
Ukuhlanganiswa kwesixhumanisi | Ukusekelwa okuhlanganisiwe kwe-Static Manual | |
Ukusekelwa kokuhlanganiswa kwe-LACP Dynamic | ||
Umuduni | Tholakala | |
Isidumbu somzimba | ||
Itbrid | ||
I-Port Port, Protocol, I-MAC-based Vlan Partishining | ||
Sekela ukubhaliswa kwe-GVRP Dynamic Vlan | ||
Voice Vlan | ||
Inzi | Ukusekelwa kwesengezo se-static, ukususwa | |
Umkhawulo we-Mac ikheli lokufunda | ||
Sekela isikhathi sokuguga esinamandla | ||
Isihlahla esigaxekile | Sekela uhlelo lwe-STP Spanning Tree Protocol | |
Isekela iphrothokholi ye-RSTP ngokushesha kwesihlahla somuthi | ||
Isekela protocol yesihlahla esisheshayo se-MSTP | ||
-Humushi | Ukusekelwa kwesengezo se-static, ukususwa | |
I-IGMP-Snooping | ||
Sekela i-mld-snooping | ||
Sekela i-V1 / 2/3 Dynamic Multicast Monitor | ||
Ddm | Sekela i-SFP / SFP + DDM | |
Umsebenzi oweluliwe | ||
Icongu | Kususelwa ku-Source Mac, indawo oyifika kuyo, uhlobo lwe-protocol, i-IP yomthombo, ukuphela | |
IP, L4 Port | ||
Isifundo | Kususelwa kuhlukanisi lwe-802.1P (COS) | |
Kususelwa ekuhlukanisweni kwe-DSCP | ||
Ukuhlukaniswa kususelwa kumthombo IP, ukuphela IP, nenombolo yePort | ||
Ukusekelwa kwe-SP, Isu lokuhlela le-WRR | ||
Ukusekela ukugeleza kwesilinganiso semoto umkhawulo wemoto | ||
I-LLDP | Ukusekelwa kwe-LLDP LLDP LAND | |
Izilungiselelo zomsebenzisi | Engeza / susa abasebenzisi | |
Ugodo | Ukungena komsebenzisi, ukusebenza, isimo, imicimbi | |
Anti-Attack | I-DOS Defense | |
Sekela ukuvikelwa kwe-CPU kanye nemikhawulo isilinganiso sokuthumela amaphakethe we-CPU | ||
I-ARP Binding (IP, Mac, Port Binding) | ||
Ukufakazela ngencwadi | Sekela ubuqiniso be-port we-802.1x | |
Sekela isitifiketi se-AAA | ||
Ukuxilongwa kwenethiwekhi | Sekela i-Ping, iTelnet, Landelela | |
Ukuphathwa kohlelo | Ukusetha kabusha Kwedivaysi, Ukucushwa Gcina / Buyisela, Ukuthuthukisa Ukuphathwa, Ukuhlelwa Kwesikhathi, njll. | |
Umsebenzi Wokuphatha | ||
Imba yenda | Ukusekelwa kwe-Serial Port Road Command Management | |
Uhlobo | Ukusekelwa kwe-SSHV1 / 2 | |
Umfanekiso | Sekela Ukuphathwa Kwe-Telnet Remote | |
Ubulembu | Amasethingi we-Support ungqimba 2, ungqimba 2 no-Layer 3 Monitor | |
I-SNMP | SNMP V1 / V2 / v3 | |
Isicupho Sesekeli: I-ColdStart, I-Flomstart, Ukuxhumanisa, Ukuxhumanisa | ||
Uhlobo lwenmonn | Sekela i-Rmon v1 | |
Inkongo | Sekela Amandla Okuphakelayo Poe | |
Eminye imisebenzi | Sekela i-DHCP Snooping, inketho82, i-DHCP Server | |
Sekela ukutholwa kwe-arp enamandla | ||
Sekela isitifiketi se-Tacacs + | ||
Ukusekelwa kwesitifiketi se-DNS | ||
Izilungiselelo Zokuphepha Kokusekela | ||
Sekela uMVr Protocol | ||
Sekela ikhebula le-Cable Detection vct | ||
Ukusekelwa kwe-UDDL Protocol |