I-TH-GC0416PM2-Z200W Isendlalelo2 Esiphethwe I-Ethernet Switch 4xGigabit Combo(RJ45/SFP) 16×10/ 100/ 1000Base-T PoE
I-Gigabit Layer 2 Managed PoE Switch iyi-Green Energy-Saving PoE Switch ngokuzimela. Nge-Network IC yekhwalithi ephezulu nenesivinini esikhulu kanye ne-PoE Chip ezinzile, izimbobo ze-PoE zihlangana ne-IEEE802.3af 15.4w kanye ne-IEEE802.3at 30w. Le modeli ingahlinzeka ngoxhumano olungenazihibe lwe-10/ 100/ 1000M Ethernet, futhi imbobo yamandla ye-PoE ingathola ngokuzenzakalelayo futhi inike amandla amadivayisi anamandla athobelana ne-IEEE802.3af/at standards. Amadivayisi we-Non-PoE anikwe amandla ngenkani futhi adlulisa idatha kuphela.
● Dlulisa idatha yamakhamera agada inethiwekhi
● 16 x 10/ 100/ 1000Mbps Izimbobo ze-PoE ezizizwa ngokuzenzakalelayo, 4 x 10/ 100/ 1000Mbps Izimbobo ze-Combo, 1 x Imbobo ye-Console
● Isekela i-IEEE802.3/ IEEE802.3i/IEEE802.3uIEEE802.3ab/IEEE802.3z, IEEE802.3af/at, isitolo-nokudlulisela phambili
● Ihambisana ne-IEEE802.3at (30W) kanye ne-IEEE802.3af (15.4w)
● Imbobo ye-Ethernet isekela i-10/ 100/ 1000M eguquguqukayo kanye nemisebenzi ye-PoE
● Inkomba yephaneli eqapha isimo kanye nokuhlaziya ukwehluleka kosizo
● Sekela ukuqinisekiswa kwembobo okungu-802.1x, isekela ukuqinisekiswa kwe-AAA, isekela ukuqinisekiswa kwe-TACACS+
● Izilungiselelo zokuvikela i-DOS, izilungiselelo ze-ACL
● Sekela iWEB, TELNET, CLI, SSH, SNMP, RMON management
● Sekela i-PoE Power Management kanye ne-PoE Watchdog
● Ukuvikelwa Kombani: Imodi Ejwayelekile 4KV, Imodi Ehlukile 2KV, ESD 15KV.
| P/N | Incazelo |
| TH-GC0416PM2-Z200W | I-Layer2 Managed Ethernet Switch 4x1Gigabit Combo(RJ45/SFP) 16×10/100/1000Base-T PoE Port, Internal Power Supply 52V/3.8A, 200w |
| TH-GC0416PM2-Z200W | I-Layer2 Managed Ethernet Switch 4x1Gigabit Combo(RJ45/SFP) 16×10/100/1000Base-T PoE Port , Ukunikezwa kwamandla kwangaphakathi 52V/5.76A, 300w |
| I/O Interface | |
| Amandla | Okokufaka kwe-AC 110-240V, 50/60Hz |
| Ulwazi Lwechweba | 16 x 10/100/1000Mbps Imbobo ye-PoE |
| 4 x 1000M Combo (RJ45/SFP) Imbobo | |
| 1 x RJ45 Console Port | |
| Ukusebenza | |
| Ukushintsha Amandla | 56Gbps |
| Okokusebenza | 41.66Mpps |
| Iphakeji Buffer | 4Mb |
| Inkumbulo ye-Flash | 16MB |
| I-DDR SDRAM | 128MB |
| Ikheli le-MAC | 8K |
| I-Jumbo Frame | 9.6Kbytes |
| Ama-VLAN | 4096 |
| Imodi yokudlulisa | Gcina futhi uye phambili |
| MTBF | 100000 amahora |
| Okujwayelekile | |
| Iphrothokholi yenethiwekhi | IEEE 802.3: Iphrothokholi ye-Ethernet MAC |
| IEEE 802.3i: 10BASE-T Ethernet | |
| IEEE 802.3u: 100BASE-TX Fast Ethernet | |
| IEEE 802.3ab: 1000BASE-T Gigabit Ethernet | |
| IEEE 802.3z: 1000BASE-X Gigabit Ethernet (fiber optical) | |
| IEEE 802.3az: I-Ethernet Eyonga Amandla | |
| IEEE 802.3ad: Indlela evamile yokwenza ukuhlanganisa isixhumanisi | |
| IEEE 802.3x: Ukulawula ukugeleza | |
| IEEE 802.1ab: LLDP/LLDP-MED (Iphrothokholi Yokutholwa Kwesendlalelo Sesixhumanisi) | |
| IEEE 802.1p: I-LAN Layer QoS/CoS Protocol Prioritization Traffic (Multicast | |
| umsebenzi wokuhlunga) | |
| IEEE 802.1q: Ukusebenza kwebhuloho le-VLAN | |
| IEEE 802.1x: Ukulawulwa Kokufinyelela Kwekhasimende/Iseva kanye Nephrothokholi Yokuqinisekisa | |
| IEEE 802.1d: STP; IEEE 802.1s: MSTP; IEEE 802.1w: RSTP | |
| Iphrothokholi ye-PoE | IEEE802.3af (15.4W); IEEE802.3at (30W) |
| Izinga Lemboni | I-EMI: I-FCC Ingxenye 15 CISPR (EN55032) isigaba A |
| I-EMS: EN61000-4-2 (ESD), EN61000-4-4 (EFT), EN61000-4-5 (Surge) | |
| Ukushaqeka: IEC 60068-2-27 | |
| Ukuwa Kwamahhala: IEC 60068-2-32 | |
| Ukudlidliza: IEC 60068-2-6 | |
| I-Network Medium | I-10Base-T: I-Cat3, 4, 5 noma ngaphezulu kwe-UTP(≤100m) |
| 100Base-TX: Cat5 noma ngaphezulu kwe-UTP(≤100m) | |
| 1000Base-TX: Cat5 noma ngaphezulu kwe-UTP(≤100m)Optical | |
| I-Multimode fiber: 1310nm, 2Km | |
| I-fiber yemodi eyodwa: 1310nm, 20/40 Km; 1550nm, 60/80/100/120Km | |
| Ukuvikelwa | |
| Isitifiketi Sokuphepha | I-CE/FCC/RoHS |
| Imvelo | |
| Indawo Yokusebenzela | Izinga Lokushisa Lokusebenza: -20 ~ 55°C |
| Izinga Lokushisa Lesitoreji: -40~85°C | |
| Umswakama osebenzayo: 10% ~ 90%, awunciphisi | |
| Izinga Lokushisa Lokugcina: 5% ~ 90%, alincishi | |
| Ubude Bokusebenza: Ubukhulu obungamamitha ayi-10,000 | |
| Isisindo sesitoreji: Ubukhulu obungamafidi angu-10,000 | |
| Inkomba | |
| Izinkomba ze-LED | I-PWR (ukunikezwa kwamandla) |
| I-SYS (Isistimu) | 1-16 PoE & ACT (PoE) |
| 1-16 Isixhumanisi & UMTHETHO (Isixhumanisi & Yenza) | |
| 17-20 Isixhumanisi (Isixhumanisi) | |
| 17-20 Act (Umthetho) | |
| Ukushintsha kwe-DIP | Setha kabusha |
| Omakhenikha | |
| Usayizi Wesakhiwo | Ubukhulu bomkhiqizo (L*W*H): 440* 284*44mm |
| Ubukhulu bephakheji (L*W*H): 495*350*103mm | |
| NW: 3.5kg | |
| Isisindo: 4.25kg | |
| Ukupakisha Ulwazi | I-Carton MEAS: 592 * 510 * 375mm |
| Ukupakisha Ubuningi: amayunithi ama-5 | |
| Isisindo Sokupakisha: 22.5KG | |
| Umsebenzi Wesoftware Yesendlalelo sesi-2 | |
| Ukuphathwa Kwechweba | Nika amandla/Khubaza Imbobo |
| Isivinini, i-Duplex, i-MTU Setting | |
| Ukulawula ukugeleza | |
| Hlola Ulwazi Lwechweba | |
| I-Port Mirroring | Isekela kokubili i-side-way port mirroring |
| I-Port Speed Limit | Isekela okokufaka okusekelwe echwebeni / ukuphathwa komkhawulokudonsa okukhiphayo |
| Ukuhlukaniswa kwePort | Sekela ukuhlukaniswa kwembobo ye-downlink, futhi ingaxhumana nembobo ye-uplink |
| Ukucindezela Kwesiphepho | Isekela i-unicast engaziwa, i-multicast, i-multicast engaziwa, ukucindezelwa kwesiphepho sohlobo lokusakaza |
| Ukucindezelwa kwesiphepho okusekelwe kumthethonqubo womkhawulokudonsa nokuhlunga kwesiphepho | |
| Ukuhlanganiswa Kwesixhumanisi | Sekela ukuhlanganisa okwenziwa ngesandla okumile |
| Sekela ukuhlanganisa okuguquguqukayo kwe-LACP | |
| I-VLAN | Ukufinyelela |
| Isiqu | |
| Ingxubevange | |
| Imbobo yokusekela, iphrothokholi, ukwahlukanisa kwe-VLAN okusekelwe ku-MAC | |
| Sekela ukubhaliswa kwe-VLAN eguqukayo ye-GVRP | |
| I-VLAN yezwi | |
| I-MAC | Sekela ukwengeza okumile, ukususwa |
| Umkhawulo wokufunda wekheli le-MAC | |
| Sekela isilungiselelo sesikhathi sokuguga esiguqukayo | |
| Isihlahla esinwebekayo | Sekela iphrothokholi yesihlahla enwebekayo ye-STP |
| Isekela i-RSTP Rapid Spanning Tree Protocol | |
| Isekela i-MSTP Rapid Spanning Tree Protocol | |
| Ukusakaza okuningi | Sekela ukwengeza okumile, ukususwa |
| I-IGMP-snooping | |
| Sekela i-MLD-Snooping | |
| Sekela i-v1/2/3 imonitha yokusakaza okuningi enamandla | |
| I-DDM | Sekela i-SFP/SFP+DDM |
| Umsebenzi Owengeziwe | |
| I-ACL | Ngokusekelwe kumthombo we-MAC, indawo ye-MAC, uhlobo lwephrothokholi, i-IP yomthombo, indawo oya kuyo |
| IP, imbobo ye-L4 | |
| QoS | Ngokusekelwe kusigaba esingu-802.1p (COS). |
| Ngokusekelwe kusigaba se-DSCP | |
| Ukuhlukaniswa ngokusekelwe ku-IP yomthombo, i-IP yendawo, kanye nenombolo yembobo | |
| Sekela i-SP, isu lokuhlela le-WRR | |
| Ukusekela isilinganiso sokugeleza komkhawulo CAR | |
| I-LLDP | Sekela iphrothokholi yokutholwa kwesixhumanisi se-LLDP |
| Izilungiselelo zomsebenzisi | Engeza/susa abasebenzisi |
| Ilogi | Ukungena ngemvume komsebenzisi, ukusebenza, isimo, imicimbi |
| Anti-attack | Ukuzivikela kwe-DOS |
| Sekela ukuvikelwa kwe-CPU futhi ukhawule izinga lokuthumela amaphakethe we-CPU | |
| Ukubophezela kwe-ARP (IP, MAC, PORT ebopha) | |
| Isitifiketi | Sekela ukuqinisekiswa kwembobo okungu-802.1x |
| Sekela isitifiketi se-AAA | |
| Ukuxilongwa kwenethiwekhi | Ukusekela i-ping, i-telnet, ukulandelela |
| Ukuphathwa Kwesistimu | Ukusetha kabusha idivayisi, ukulungisa londoloza/buyisela, thuthukisa ukuphathwa, ukulungiselelwa kwesikhathi, njll. |
| Umsebenzi wokuphatha | |
| I-CLI | Sekela ukuphathwa komugqa womyalo we-serial port |
| I-SSH | Sekela ukuphathwa okukude kwe-SSHv1/2 |
| I-TELNET | Sekela ukuphathwa okukude kwe-telnet |
| IWEBH | Izilungiselelo ze-Support Layer 2, Layer 2 kanye ne-Layer 3 monitor |
| I-SNMP | I-SNMP V1/V2/V3 |
| Uxhaso lokusekela: ColdStart, WarmStart, LinkDown, LinkUp | |
| I-RMON | Sekela i-RMON v1 |
| I-PoE | Ukusekela ukunikezwa kwamandla kwe-PoE |
| Eminye imisebenzi | Sekela i-DHCP Snooping, Option82, iseva ye-DHCP |
| Sekela ukutholwa kwe-ARP enamandla | |
| Sekela isitifiketi se-TACACS+ | |
| Sekela isitifiketi se-DNS | |
| Sekela izilungiselelo zokuphepha kwembobo | |
| Sekela iphrothokholi ye-MVR | |
| Sekela ukutholwa kwekhebula umsebenzi we-VCT | |
| Sekela iphrothokholi ye-UDLD | |